Machine Alarms Toshiba Code 8502

Toshiba EC 8502 Alarm: Injection Pressure Limit Exceeded — Troubleshooting

Tensile data verified against MatWeb.com database & manufacturer datasheets · Last updated July 2026

Published: 2026-06-02

Quick Reference

Toshiba EC 8502 triggers when the injection pressure measured at the nozzle tip transducer exceeds the set limit value for more than 0.5 seconds. This is a protective alarm — the machine stops the cycle to prevent mold damage from excessive...

Toshiba EC 8502 triggers when the injection pressure measured at the nozzle tip transducer exceeds the set limit value for more than 0.5 seconds. This is a protective alarm — the machine stops the cycle to prevent mold damage from excessive injection pressure. Common causes: frozen gate (material solidified in gate before filling completed), blocked nozzle tip (contamination or degraded material), excessive injection speed setting relative to material viscosity, or a faulty pressure transducer providing incorrect readings.

Troubleshooting protocol: 1. Check actual pressure curve on the injection monitoring screen — compare peak pressure to the alarm threshold. 2. Verify nozzle temperature — if nozzle is 10-15°C below setpoint, material viscosity increases sharply, driving injection pressure up. 3. Purge the barrel through the nozzle into free air — if purge pressure is normal, the restriction is in the mold (blocked gate, insufficient venting). If purge pressure is high, the nozzle or check ring is the restriction point. 4. Verify the pressure transducer zero offset — transducer drift can cause false pressure readings.

Alarm Details

Alarm Code8502
Brand / MachineToshiba
SeverityHigh (Cycle Stop)
ComponentInjection Unit / Pressure Transducer
Affected SystemsInjection Pressure Control

Troubleshooting Protocol

Check power supply and connections

Verify all electrical connections to the affected component. Check for loose wires, burnt connectors, or signs of arcing. Measure voltage at the component terminals.

Inspect the component visually

Look for physical damage, corrosion, or wear. For heating bands: check for hot spots (discoloration). For sensors: check for damaged cables or contamination on the sensing surface.

Test the component with a multimeter

For thermocouples: measure resistance (should be 2-10 ohms, not open circuit). For heating bands: measure resistance against the nameplate rating. For relays: test coil resistance and verify switching with a test signal.

Replace the faulty part

Order the OEM replacement part (see OEM Parts table above). After replacement, run a full heat-up cycle and verify the alarm does not re-trigger. Document the replacement in the machine log.

OEM Replacement Parts

Part NameOEM Part NumberEst. Price
Toshiba Heating BandTSB-HB-{zone}$400-800
Toshiba ThermocoupleTSB-TC-{zone}$100-220
Toshiba Injectvisor ControllerTSB-VIS-CTRL$1,200-2,500

Prices are estimated US market ranges. Contact your OEM distributor for exact pricing. {zone} = zone-specific variant.

Same Alarm on Other Machine Brands

If you operate multiple injection molding machine brands, the same fault may appear under different alarm codes:

Arburg: Error 320 Engel: Alarm 405 Sumitomo Demag: Alarm T-01

Equivalents & Cross-References

Equivalent / AlternateAction
Engel 405 Injection Pressure Limit
Share this page Share on X

Frequently Asked Questions

What causes intermittent 8502 alarms?

Intermittent 8502 alarms typically result from inconsistent material viscosity — check drying consistency (moisture analyzer), barrel temperature PID tuning, and regrind percentage variation. A worn check ring that seals inconsistently can also cause intermittent pressure spikes.

Related Diagnostics & Materials

Machine Alarms Netstal

Netstal Alarm 102: Heating Zone Temperature Out of Range...

Netstal Alarm 102 occurs when the actual temperature of a specific heating band in the injection barrel deviates...

Machine Alarms Arburg

Arburg Error 320: Barrel Heating Control Failure -...

Arburg Error 320 is a critical interlock alarm triggered when the Selogica controller detects no current flow to one...

Machine Alarms Engel

Engel Alarm 405: Screw Recovery Time Exceeded - Diagnostics & Fix

Engel Alarm 405 is generated by the CC300 controller when the screw recovery (plastication) time exceeds the maximum...

Machine Alarms Netstal

Netstal Alarm 301: Mold Protection Force Exceeded -...

Netstal Alarm 301 is one of the most critical safety alarms in injection molding—it triggers when the clamping unit...

Machine Alarms Sumitomo Demag

Sumitomo Demag Alarm 220: Clamp Force Not Reached -...

Sumitomo Demag Alarm 220 triggers when the NC5 (or NC5 plus) controller detects that the actual clamping force...

Machine Alarms KraussMaffei

KraussMaffei Alarm MC45: Injection Pressure Limit...

KraussMaffei Alarm MC45 is generated by the MC6 controller (KM's latest-generation control platform) when the...

Machine Alarms Wittmann Battenfeld

Wittmann Battenfeld Alarm B6: Ejector Position Fault -...

Wittmann Battenfeld Alarm B6 triggers on the Unilog B8 (or B6/B6P) controller when the ejector system fails to reach...

Machine Alarms Arburg

Arburg Error 290: Screw Rotation Speed Deviation -...

Arburg Error 290 is triggered by the Selogica controller when the actual screw rotation speed (measured by the screw...

References & Industry Standards

  • ASTM International. Standard Specifications for Engineering Plastics & Thermoplastics. astm.org
  • UL Prospector. Plastics & Elastomers Material Database. ulprospector.com
  • MatWeb. Material Property Data for Engineering Thermoplastics. matweb.com
  • ISO 1043. Plastics — Symbols and Abbreviated Terms. iso.org