Machine Alarms Sumitomo Demag Code 350

Sumitomo Demag Alarm 350: Clamp Force Deviation — Complete Troubleshooting

Published: 2026-05-28

Quick Reference

Sumitomo Demag Alarm 350 indicates that the measured clamp force deviates from the setpoint by more than the safety margin (±8% on most SD machines). This can mean either insufficient clamp force (flash risk during injection) or excessive clamp...

Sumitomo Demag Alarm 350 indicates that the measured clamp force deviates from the setpoint by more than the safety margin (±8% on most SD machines). This can mean either insufficient clamp force (flash risk during injection) or excessive clamp force (mold and tie bar damage).

Step-by-Step Diagnostic

1. Verify actual clamp force with a magnetic-base dial indicator on the tie bar (measure tie bar stretch and convert to force using Hooke's Law). 2. Check tie bar strain gauge calibration — perform a zero-point reset following the machine manual's procedure. 3. Inspect mold height setting — incorrect mold height forces the clamping system to compensate, triggering the alarm. 4. Check hydraulic clamp pressure transducer — a failing transducer provides incorrect pressure feedback to the controller. 5. Inspect tie bar nuts for loosening — a single loose tie bar shifts the entire clamp force distribution.

Alarm Details

Alarm Code350
Brand / MachineSumitomo Demag
SeverityCritical (Mold Protection — Immediate Stop)
ComponentClamp Force Transducer / Tie Bar Strain Gauge
Affected SystemsClamping Unit — Force Control Loop

Troubleshooting Protocol

Check the Controller Diagnostic Screen

Identify which zone/component triggered the alarm. Record the error code, timestamp, and any measured deviation values shown on the diagnostic screen.

Perform Visual Inspection (LOTO First)

Power down the machine and follow Lock-Out Tag-Out procedures. Visually inspect the affected component for physical damage, loose connections, polymer leakage, or carbonized material.

Electrical Testing

Using a multimeter, check resistance/continuity on the affected circuit. Verify SSR functionality and fuse integrity. Compare readings to OEM specifications.

Replace Faulty Component

Replace the failed component with an OEM-approved part. Do not substitute with generic equivalents unless validated for the specific machine model and operating conditions.

Verify and Document

Restart the machine, verify the alarm is cleared, run a test cycle, and document the root cause, repair performed, and parts replaced in the machine maintenance log.

Equivalents & Cross-References

Equivalent / AlternateAction
engel-alarm-510
krauss-maffei-mc100-hydraulic-system

Related Diagnostics & Materials

Machine Alarms Netstal

Netstal Alarm 102: Heating Zone Temperature Out of Range...

Netstal Alarm 102 occurs when the actual temperature of a specific heating band in the injection barrel deviates...

Machine Alarms Arburg

Arburg Error 320: Barrel Heating Control Failure -...

Arburg Error 320 is a critical interlock alarm triggered when the Selogica controller detects no current flow to one...

Machine Alarms Engel

Engel Alarm 405: Screw Recovery Time Exceeded - Diagnostics & Fix

Engel Alarm 405 is generated by the CC300 controller when the screw recovery (plastication) time exceeds the maximum...

Machine Alarms Netstal

Netstal Alarm 301: Mold Protection Force Exceeded -...

Netstal Alarm 301 is one of the most critical safety alarms in injection molding—it triggers when the clamping unit...

Machine Alarms Sumitomo Demag

Sumitomo Demag Alarm 220: Clamp Force Not Reached -...

Sumitomo Demag Alarm 220 triggers when the NC5 (or NC5 plus) controller detects that the actual clamping force...

Machine Alarms KraussMaffei

KraussMaffei Alarm MC45: Injection Pressure Limit...

KraussMaffei Alarm MC45 is generated by the MC6 controller (KM's latest-generation control platform) when the...

Machine Alarms Wittmann Battenfeld

Wittmann Battenfeld Alarm B6: Ejector Position Fault -...

Wittmann Battenfeld Alarm B6 triggers on the Unilog B8 (or B6/B6P) controller when the ejector system fails to reach...

Machine Alarms Arburg

Arburg Error 290: Screw Rotation Speed Deviation -...

Arburg Error 290 is triggered by the Selogica controller when the actual screw rotation speed (measured by the screw...

References & Industry Standards

  • ASTM International. Standard Specifications for Engineering Plastics & Thermoplastics. astm.org
  • UL Prospector. Plastics & Elastomers Material Database. ulprospector.com
  • MatWeb. Material Property Data for Engineering Thermoplastics. matweb.com
  • ISO 1043. Plastics — Symbols and Abbreviated Terms. iso.org