Sumitomo Demag Alarm 700: Robot Interface Communication Loss
Published: 2026-06-02
EU67/SPI robot communication lost. Machine cannot confirm robot clear of mold. Check EU67 cable continuity, loose pins, and route comm cables >300mm from VFD motor cables.
EU67/SPI robot communication lost. Machine cannot confirm robot clear of mold. Check EU67 cable continuity, loose pins, and route comm cables >300mm from VFD motor cables.
Alarm Details
| Alarm Code | 700 |
|---|---|
| Brand / Machine | Sumitomo Demag |
| Severity | High (Automation Stop) |
| Component | Euromap 67 Interface / Robot |
| Affected Systems | Robot-Machine Communication |
Troubleshooting Protocol
Identify which zone/component triggered the alarm. Record the error code, timestamp, and any measured deviation values shown on the diagnostic screen.
Power down the machine and follow Lock-Out Tag-Out procedures. Visually inspect the affected component for physical damage, loose connections, polymer leakage, or carbonized material.
Using a multimeter, check resistance/continuity on the affected circuit. Verify SSR functionality and fuse integrity. Compare readings to OEM specifications.
Replace the failed component with an OEM-approved part. Do not substitute with generic equivalents unless validated for the specific machine model and operating conditions.
Restart the machine, verify the alarm is cleared, run a test cycle, and document the root cause, repair performed, and parts replaced in the machine maintenance log.
Equivalents & Cross-References
| Equivalent / Alternate | Action |
|---|---|
| Engel Robot Interface |
Frequently Asked Questions
What is Euromap 67?
Standard 24VDC interface between IMM and robot. Defines signals: Mold Open, Robot In Mold, Robot Clear, Ejector Retracted.
Related Diagnostics & Materials
Netstal Alarm 102: Heating Zone Temperature Out of Range...
Netstal Alarm 102 occurs when the actual temperature of a specific heating band in the injection barrel deviates...
Arburg Error 320: Barrel Heating Control Failure -...
Arburg Error 320 is a critical interlock alarm triggered when the Selogica controller detects no current flow to one...
Engel Alarm 405: Screw Recovery Time Exceeded - Diagnostics & Fix
Engel Alarm 405 is generated by the CC300 controller when the screw recovery (plastication) time exceeds the maximum...
Netstal Alarm 301: Mold Protection Force Exceeded -...
Netstal Alarm 301 is one of the most critical safety alarms in injection molding—it triggers when the clamping unit...
Sumitomo Demag Alarm 220: Clamp Force Not Reached -...
Sumitomo Demag Alarm 220 triggers when the NC5 (or NC5 plus) controller detects that the actual clamping force...
KraussMaffei Alarm MC45: Injection Pressure Limit...
KraussMaffei Alarm MC45 is generated by the MC6 controller (KM's latest-generation control platform) when the...
Wittmann Battenfeld Alarm B6: Ejector Position Fault -...
Wittmann Battenfeld Alarm B6 triggers on the Unilog B8 (or B6/B6P) controller when the ejector system fails to reach...
Arburg Error 290: Screw Rotation Speed Deviation -...
Arburg Error 290 is triggered by the Selogica controller when the actual screw rotation speed (measured by the screw...
References & Industry Standards
- ASTM International. Standard Specifications for Engineering Plastics & Thermoplastics. astm.org
- UL Prospector. Plastics & Elastomers Material Database. ulprospector.com
- MatWeb. Material Property Data for Engineering Thermoplastics. matweb.com
- ISO 1043. Plastics — Symbols and Abbreviated Terms. iso.org