Quick Reference

KraussMaffei MC120: actual back pressure deviates >15% from setpoint. Critical for melt homogeneity. Causes: proportional valve sticking, transducer drift, air in hydraulic system.

KraussMaffei MC120: actual back pressure deviates >15% from setpoint. Critical for melt homogeneity. Causes: proportional valve sticking, transducer drift, air in hydraulic system.

Alarm Details

Alarm CodeMC120
Brand / MachineKraussMaffei
SeverityMedium (Cycle Alarm)
ComponentBack Pressure Valve / Transducer
Affected SystemsPlasticating Back Pressure Control

Troubleshooting Protocol

Check power supply and connections

Verify all electrical connections to the affected component. Check for loose wires, burnt connectors, or signs of arcing. Measure voltage at the component terminals.

Inspect the component visually

Look for physical damage, corrosion, or wear. For heating bands: check for hot spots (discoloration). For sensors: check for damaged cables or contamination on the sensing surface.

Test the component with a multimeter

For thermocouples: measure resistance (should be 2-10 ohms, not open circuit). For heating bands: measure resistance against the nameplate rating. For relays: test coil resistance and verify switching with a test signal.

Replace the faulty part

Order the OEM replacement part (see OEM Parts table above). After replacement, run a full heat-up cycle and verify the alarm does not re-trigger. Document the replacement in the machine log.

OEM Replacement Parts

Part NameOEM Part NumberEst. Price
KraussMaffei OEM Heating BandKM-HB-{zone}$500-950
KraussMaffei ThermocoupleKM-TC-{zone}$140-300
KraussMaffei MC6 Temperature BoardKM-MC6-TC$1,800-3,500
KraussMaffei Relay CardKM-MC6-RELAY$450-900

Prices are estimated US market ranges. Contact your OEM distributor for exact pricing. {zone} = zone-specific variant.

Same Alarm on Other Machine Brands

If you operate multiple injection molding machine brands, the same fault may appear under different alarm codes:

Arburg: Error 320 Engel: Alarm 405 Sumitomo Demag: Alarm T-01

Equivalents & Cross-References

Equivalent / AlternateAction
Engel 405
Share this page Share on X

Frequently Asked Questions

Recommended back pressure for engineering resins?

Unfilled (PC, PMMA, PSU): 5-10 bar. Glass-filled (PA66 GF30): 3-5 bar to minimize fiber breakage. POM: 2-5 bar max (excess back pressure degrades POM).

Related Diagnostics & Materials

Machine Alarms Netstal

Netstal Alarm 102: Heating Zone Temperature Out of Range...

Netstal Alarm 102 occurs when the actual temperature of a specific heating band in the injection barrel deviates...

Machine Alarms Arburg

Arburg Error 320: Barrel Heating Control Failure -...

Arburg Error 320 is a critical interlock alarm triggered when the Selogica controller detects no current flow to one...

Machine Alarms Engel

Engel Alarm 405: Screw Recovery Time Exceeded - Diagnostics & Fix

Engel Alarm 405 is generated by the CC300 controller when the screw recovery (plastication) time exceeds the maximum...

Machine Alarms Netstal

Netstal Alarm 301: Mold Protection Force Exceeded -...

Netstal Alarm 301 is one of the most critical safety alarms in injection molding—it triggers when the clamping unit...

Machine Alarms Sumitomo Demag

Sumitomo Demag Alarm 220: Clamp Force Not Reached -...

Sumitomo Demag Alarm 220 triggers when the NC5 (or NC5 plus) controller detects that the actual clamping force...

Machine Alarms KraussMaffei

KraussMaffei Alarm MC45: Injection Pressure Limit...

KraussMaffei Alarm MC45 is generated by the MC6 controller (KM's latest-generation control platform) when the...

Machine Alarms Wittmann Battenfeld

Wittmann Battenfeld Alarm B6: Ejector Position Fault -...

Wittmann Battenfeld Alarm B6 triggers on the Unilog B8 (or B6/B6P) controller when the ejector system fails to reach...

Machine Alarms Arburg

Arburg Error 290: Screw Rotation Speed Deviation -...

Arburg Error 290 is triggered by the Selogica controller when the actual screw rotation speed (measured by the screw...

References & Industry Standards

  • ASTM International. Standard Specifications for Engineering Plastics & Thermoplastics. astm.org
  • UL Prospector. Plastics & Elastomers Material Database. ulprospector.com
  • MatWeb. Material Property Data for Engineering Thermoplastics. matweb.com
  • ISO 1043. Plastics — Symbols and Abbreviated Terms. iso.org